4.6 <REFERENCE>(XRP) Self-Test Results:
Console Display
You can check <REFERENCE>(XRP) self-test results in three
ways: the self-test display, the lights on the module, and the
contents of the XGPR register. Pertinent information in the
self-test display is shown in Example 4–2. See Chapter 6 for
information on vector processors.
Example 4–2: Self-Test Results
#123456789 0123456789 0123456789 01234567#
1
F E D C B A 9 8 7 6 5 4 3 2 1 0 NODE #
A A . . M M M M . . P P P P TYP
2
o + . . + + + + . . + + + + STF
3
. . . . . . . . . . E E D B BPD
4
. . . . . . . . . . + + + - ETF
5
. . . . . . . . . . E B D E BPD
6
. . . . . . + + . + . + . + + . XBI E +
. . . . A4 A3 A2 A1 . . . . . . ILV
. . . . 128 128 128 128 . . . . . . 512Mb
ROM0 = V3.00 ROM1 = V3.00 EEPROM = 2.03/3.00 SN = SG01234567
7
>>>
1
The first line of the self-test printout is the progress trace. This line
prints if a <REFERENCE>(XRP) module is in slot 1. The progress
trace has two purposes: to give a visual indication that the system
is functioning during self-test, and, if self-test fails, to display the
failing test number. The numbers correspond to the 37 tests in the
<REFERENCE>(XRP) self-test. When self-test passes, the line prints
as in Example 4–2. If a test fails, the failing test number is the last
one printed. For example, if test 14 fails, the line is printed as follows:
#123456789 01234
4–18 VAX 6000 Models 300 and 400 Service Manual