Table 3–8 (Cont.): Machine Check Parameters
Parameter Value Description
8 Process PTE in P1 space during
M = 0 flows
9 Undefined INT.ID value
A Undefined MOVCx state
80 Memory read error
81 SCB, PCB, or SPTE read error
82 Memory write error
83 SCB, PCB, or SPTE write error
Most recent virtual address
(SP+8)
<31:0> Current contents of VAP register
Internal state information #1
(SP+C)
<31:24> Opcode
<23:16> 1110, highest priority software inter-
rupt <3:0>
<15:8> CADR<7:0>
<7:0> MSER<7:0>
Internal state information #2
(SP+10)
<31:24> Most recent contents of SC register <7:0>
<23:16> 11, state flags <5:0>
<15:8> Restart flag, 111, ALU CC flags <3:0>
<7:0> Offset from saved PC to PC at time of ma-
chine check
PC
(SP+14)
<31:0> PC at the start of the current instruc-
tion
PSL
(SP+18)
<31:0> Current contents of PSL
Machine checks are taken regardless of the current IPL. During a machine
check the IPL is raised to 1F and the machine check frame is pushed onto
the interrupt stack. If the machine check exception vector bits (<1:0>) are
not both one, the operation of the processor is undefined.
<REFERENCE>(xyp) Scalar Processor 3–37