PROBLEM
A trap-1 brings down tlie
operating
system when a less radical action would be
better;
ie. a program
that
accidentally writes off
the
end of
the
dimensioned array. A trap-1
is
appropriate
when invalid instructions are
encountered,
but
should
not
crash a MULTI-user system (it can
just
kill the process).
68000
MOVEC
INSTRUCTION
ERROR
PRODUCT
68000 assembler
and
bad
code for
MOYEe
instruction
CONFIGURATION
8560
TNIX
version 2.0
and
68000 assembler version 2.01-08
PROBLEM
The 68000 assembler produces
bad
code for the following instruction MOYEC with VBR
or
USP
as
the
operand.
For
example, MOYEC AQ, VBR generates 4E7B 8B01
and
should produce 4E7B 8801.
The
Motorola spec
sheet
is
wrong. This caused the assembler to produce
bad
code.
ACE
EDIT
OF
READ
ONLY
FILES
PRODUCT
ACE
editing read only
files
CONFIGURATION
8560
TNIX
V2.0,
ACE
V3.00
PROBLEM
Version 3.0 of
ACE
will
not
let a user read a
file
(with read only capability)
into
the
current
edit
session. A brief
error message (system function error
#-
13)
is
generated.
The
workaround
is
to
chmod to
rw
capability before
entering
ACE.
The
previous version of
ACE
did allow this.
COMMENTS
Workaround--chmod
to
rw capability all files before editing.
December 1983
TEKTRONIX